Forwarded from SimonDVD
https://mercyforanimals.org/blog/chickens-fire/
https://www.nytimes.com/2020/12/17/us/farm-fire-chickens-fl.html
https://www.wdhn.com/news/100000-chickens-killed-in-fire-at-one-of-countrys-top-egg-producers/
https://www.wattagnet.com/egg/article/15669712/us-oakdell-egg-farms-loses-over-100000-birds-to-fire
https://www.wattagnet.com/egg/article/15663527/multiday-fire-breaks-out-at-us-mps-egg-farms-facility
https://www.cbsnews.com/news/egg-industry-chicken-deaths-bird-flu/
https://www.nytimes.com/2020/12/17/us/farm-fire-chickens-fl.html
https://www.wdhn.com/news/100000-chickens-killed-in-fire-at-one-of-countrys-top-egg-producers/
https://www.wattagnet.com/egg/article/15669712/us-oakdell-egg-farms-loses-over-100000-birds-to-fire
https://www.wattagnet.com/egg/article/15663527/multiday-fire-breaks-out-at-us-mps-egg-farms-facility
https://www.cbsnews.com/news/egg-industry-chicken-deaths-bird-flu/
Mercy For Animals
Farm Says “No One Was Injured” After 200,000 Chickens Die in Fire
A massive fire at an egg farm in Wright County, Minnesota, burned down a barn housing tens of thousands of chickens.
🤬16🤨12😢6🤔1🤡1
https://www.youtube.com/watch?v=n5EoTwUVxkA
Direct 48v generator that's integrated into the victron ecosystem.
Direct 48v generator that's integrated into the victron ecosystem.
YouTube
Victron-Hatz fiPMG Genset Integration VRM View
The Hatz fiPMG is a fixed-magnet, CAN bus-controlled diesel generator in a very compact, fuel-efficient package. Check out what you can see and control remotely in a Victron power system with a communicating Hatz DC gen set.
📍 Hatz fiPMG generator product…
📍 Hatz fiPMG generator product…
❤3🤡1
Forwarded from Codar's Meme Repository: New Edition Edition 🦁🪽 (Codar)
This media is not supported in your browser
VIEW IN TELEGRAM
😁40❤1🤡1
A very odd thing happened at 3am this morning... my local power utility frequency dropped to just below 59hz and that caused my inverter to go off-grid. The voltage also rose a little bit but not out of spec.
FWIW, utility grids have to run the frequency a little high or a little low each day, usually in the morning hours to make up for gained or lost 60hz cycles thru the day. Guess they took it a little too low tonight.
FWIW, utility grids have to run the frequency a little high or a little low each day, usually in the morning hours to make up for gained or lost 60hz cycles thru the day. Guess they took it a little too low tonight.
👍7⚡1
When setting up a generator, set the RPM to 3720rpm (3600rpm unit) or 1860rpm (1800rpm) unit. Most mechanics have a tach but not a volt meter with a frequency function. What you are looking for is 62hz-62.5hz.
Another thing worth noting is that most generators do NOT have a set of contactors to drop the load when you switch them off. The problem is that when you kill them with a load on them as they spool down the armature current spikes and will burn up things inside as it tries to keep making 120/240v. It also makes for a very unstable AC waveform in your house and may damage some of your equipment.
On my onan pad mounted generator, I put a contactor inline with the 240v from the genset that energizes on the start wire. So when the start signal drops, so does this contactor.
Here's a snippet from an onan manual about setting the rpm of the generator.
Another thing worth noting is that most generators do NOT have a set of contactors to drop the load when you switch them off. The problem is that when you kill them with a load on them as they spool down the armature current spikes and will burn up things inside as it tries to keep making 120/240v. It also makes for a very unstable AC waveform in your house and may damage some of your equipment.
On my onan pad mounted generator, I put a contactor inline with the 240v from the genset that energizes on the start wire. So when the start signal drops, so does this contactor.
Here's a snippet from an onan manual about setting the rpm of the generator.