Many inverters come with a "dry contact" that you can use for a generator start. This is not exactly true. The problem is that when voltage gets below the start point, the dry contact will close. As soon as the batteries charge a tiny bit, the dry contact will open and shut off the generator.
For a typical inverter "dry contact" to work as a gen start, you need at least an "off delay" relay to ensure that if the generator starts it will run for ~30minutes once triggered to start.
More advanced inverters will have programming that includes warm up and cool down, and min run time.
For a typical inverter "dry contact" to work as a gen start, you need at least an "off delay" relay to ensure that if the generator starts it will run for ~30minutes once triggered to start.
More advanced inverters will have programming that includes warm up and cool down, and min run time.
💯2👍1
❤1👍1
Make an insulated ICF slab. https://www.youtube.com/watch?v=JqteJAFxP7g
YouTube
A NEW WAY TO BUILD A POLE BARN HOUSE !!
Here we are building a foundation for a pole barn or Bardominium or barn home as some call it. It was not built like usual with wood poles in the ground. This one was a frost protected mono slab with metal wet set brackets built by Perma Column. We also…
❤5
If anyone is interested in purchasing lifepo4 batteries now is the time... I have put together several large battery orders to get the best price possible and if we can get a total of 150 battery cells ordered we get the best price possible... We have approximately 10-14 days to get an order put together... Please PM me with any questions or would like to be put in the group to purchase batteries. Wes has been involved if you would like a reference of the long term usage of them.
Been using the backhoe so much that my brain has wired to it. but if you asked me which way to move the stick to bring the elbow in I couldn't tell you.... but if I just treat it as an extension of my body, "it just works".
🏆17🔥4
I'd like to get a weigh in from the group on something. A buddy here and I were discussing his tiny house and he said he'll use a mini split for air conditioning but he will use electric oil immersion heaters in the winter. I advised him to use the mini split because the electric resistance heater is only 100% efficient but COP on heat pump is 3:1 or 5:1 depending on outside temperature.
What say the group?
What say the group?
Hey I got a local guy who bought the wrong victron Multiplus II unit and would like to sell it. Never been in service. 3.5kw, 120voutput, 48v battery unit. Wants $1000 OBO. Perfect unit for an RV. Can be stacked with another 3.5kw unit.
My friend's problem is that you can't mix and match these units and he has two additional 5kw units that he cannot use with this one... so he will replace this unit with another 5kw unit.
My friend's problem is that you can't mix and match these units and he has two additional 5kw units that he cannot use with this one... so he will replace this unit with another 5kw unit.